/SCWM/TMFSCP - Communication Points
Communication Points information is stored in SAP table /SCWM/TMFSCP.
It is part of development package /SCWM/MFS in software component SCM-EWM. This development package consists of objects that can be grouped under "Material Flow Systems".
It is part of development package /SCWM/MFS in software component SCM-EWM. This development package consists of objects that can be grouped under "Material Flow Systems".
Fields for table /SCWM/TMFSCP
Field Name | Description | Is Key | Data Element | Data Type | Length | Check Table |
|---|---|---|---|---|---|---|
| MANDT | Client | X | MANDT | CLNT | 6 | |
| LGNUM | Warehouse Number/Warehouse Complex | X | /SCWM/LGNUM | CHAR | 8 | /SCWM/T300 |
| PLC | Programmable Logic Controller | X | /SCWM/DE_MFSPLC | CHAR | 16 | /SCWM/TMFSPLC |
| CP | Communication Point for Conveyor Technique | X | /SCWM/DE_MFSCP | CHAR | 36 | |
| CP_TYPE | Communication Point Type | /SCWM/DE_MFSCP_TYPE | CHAR | 8 | /SCWM/TMFSCPTYP | |
| CP_CLARIFY | Clarif. Comm.Point | /SCWM/DE_MFSCP_CLARIFY | CHAR | 36 | /SCWM/TMFSCP | |
| PLC_CLARIFY | SPS for Clarification Communication Point | /SCWM/DE_MFSPLC_CLARIFY | CHAR | 16 | /SCWM/TMFSPLC | |
| NOCHK_CLARI | Do Not Check Clarification Communication Point Status | /SCWM/DE_MFSNOCHK_CLA | CHAR | 2 | ||
| NOCHK_CLARI_CAPA | Do Not Check Clarification Communication Point Capacity | /SCWM/DE_MFSNOCHK_CLA_CAPA | CHAR | 2 | ||
| FLG_START | Indicator Whether Communication Point Is ID Point of Leg | /SCWM/DE_MFSCP_START | CHAR | 2 | ||
| FLG_END | Indicator Whether Communication Point is End Date of a Leg | /SCWM/DE_MFSCP_END | CHAR | 2 | ||
| FLG_NIO | Indicator Whether Communication Point Is a Clarific. Bin | /SCWM/DE_MFSCP_CHK | CHAR | 2 | ||
| FLG_SCAN | Indicator if Communication Point is a Scanner Point of Leg | /SCWM/DE_MFSCP_SCAN | CHAR | 2 | ||
| LGPLA | Storage Bin | /SCWM/LGPLA | CHAR | 36 | /SCWM/LAGP | |
| NO_FOLLUP | Do Not Create Follow-Up Warehouse Task | /SCWM/DE_MFS_NO_FOLLUP | CHAR | 2 | ||
| FLG_HU_CLR_ERR | Delete HU Error Code | /SCWM/DE_MFSCP_CLR_ERR | CHAR | 2 | ||
| PROCTYPE | Warehouse Process Type for Putaways with Conveyor Technique | /SCWM/DE_MFSPTWY_PRCTYP | CHAR | 8 | /SCWM/T333 | |
| EXCCODE_CAPA | Exception Code for Capacity Overrun | /SCWM/DE_MFSEXCCODE_CAPA | CHAR | 8 | /SCWM/TEXCEP | |
| CAPACITY | Capacity of a Segment | /SCWM/DE_MFSHU_NO | INT2 | 2 | ||
| CAPA_MODE | Capacity Mode of Communication Point | /SCWM/DE_MFS_CP_CAPA_MODE | CHAR | 2 | ||
| LGTYP_CLF | Storage Type Clarification Bin | /SCWM/DE_MFS_LGTYP_CLF | CHAR | 8 | /SCWM/T301 | |
| LGBER_CLF | Storage Section Clarification Bin | /SCWM/DE_MFS_LGBER_CLF | CHAR | 8 | /SCWM/T302 | |
| LGPLA_CLF | Clarification Storage Bin | /SCWM/DE_MFS_LGPLA_CLF | CHAR | 36 | ||
| PT_CLF | Warehouse Process Type Clarification Bin | /SCWM/DE_MFS_PT_CLF | CHAR | 8 | /SCWM/T333 | |
| LOGGING | Logging On/Off | /SCWM/DE_MFSLOG | CHAR | 2 | ||
| CP_STEP | Processing Step of a Reorder Point | /SCWM/DE_MFSCP_STEP | CHAR | 4 | ||
| HUIDENT | Handling Unit Identification | /SCWM/DE_HUIDENT | CHAR | 40 | ||
| TELTYP_RCV | Telegram Type of Receiving Telegram | /SCWM/DE_MFSTELETYPE_RCV | CHAR | 8 | ||
| TELTYP_RCV_L | Telegram Type of Last Receiving Telegram | /SCWM/DE_MFSTELETYPE_RCV_L | CHAR | 8 | ||
| SN_RCV | Receiving Telegram Sequence Number | /SCWM/DE_MFSSN_RCV | NUMC | 40 | ||
| SN_SND | Sequence Number of Sending Telegram | /SCWM/DE_MFSSN_SND | NUMC | 40 | ||
| TELE_RCV | Receiving Telegram | /SCWM/DE_MFSTELE_RCV | CHAR | 510 | ||
| TELE_SND | Sent Telegram | /SCWM/DE_MFSTELE_SND | CHAR | 510 | ||
| SN_RCV_L | Sequence Number of Last Receiving Telegram | /SCWM/DE_MFSSN_RCV_L | NUMC | 40 | ||
| SN_SND_L | Sequence Number of Last Sending Telegram | /SCWM/DE_MFSSN_SND_L | NUMC | 40 | ||
| TELE_RCV_L | Last Receiving Telegram | /SCWM/DE_MFSTELE_RCV_L | CHAR | 510 | ||
| TELE_SND_L | Last Sent Telegram | /SCWM/DE_MFSTELE_SND_L | CHAR | 510 | ||
| TS_RCV | Time Stamp of Receiving Telegram | /SCWM/DE_MFSTS_RCV | DEC | 11 | ||
| TS_SND | Time Stamp of Sending Telegram | /SCWM/DE_MFSTS_SND | DEC | 11 | ||
| TS_RCV_L | Time Stamp of Last Receiving Telegram | /SCWM/DE_MFSTS_RCV_L | DEC | 11 | ||
| TS_SND_L | Time Stamp of Last Sending Telegram | /SCWM/DE_MFSTS_SND_L | DEC | 11 | ||
| COUNT_RCV | Receiving Telegrams Counter | /SCWM/DE_MFSCNT_RCV | INT4 | 4 | ||
| COUNT_SND | Sending Telegrams Counter | /SCWM/DE_MFSCNT_SND | INT4 | 4 | ||
| TS_CNT_START | Timestamp for Last Reset | /SCWM/DE_MFSCNT_START | DEC | 8 | ||
| USER_RESET | Last Changed By | /SCWM/DE_USER_CHANGE | CHAR | 24 | ||
| TO_ERROR | Error While Creating Warehouse Task in MFS | /SCWM/DE_WT_ERROR | CHAR | 160 | ||
| PMAT | Packaging Material for Creating Unknown HU | /SCWM/DE_MFSPMAT | CHAR | 80 | ||
| CPGRP | Communication Point Group for Conveyor Technique | /SCWM/DE_MFSCPGRP | CHAR | 8 | /SCWM/TMFSCPGRP | |
| RETRY_WAIT | Interval for Telegram Retry | /SCWM/DE_MFSRETRY_WAIT_Q | NUMC | 4 |