/PLMB/BA_CCK - Messages for Compliance Check
The following messages are stored in message class /PLMB/BA_CCK: Messages for Compliance Check.
It is part of development package /PLMB/BA_CCK in software component PLM-WUI-RCP. This development package consists of objects that can be grouped under "PLM Base: Compliance Check".
It is part of development package /PLMB/BA_CCK in software component PLM-WUI-RCP. This development package consists of objects that can be grouped under "PLM Base: Compliance Check".
Message Nr ▲ | Message Text |
|---|---|
| 000 | Invalid input value |
| 001 | Some input values were invalid |
| 002 | Select a line in the Parameters for Constraint Validity list |
| 003 | There are no objects for which you can run the compliance check |
| 004 | Enter the data origin |
| 005 | Fill in the data source (Rating and Validity Area) completely |
| 006 | Select a process mode |
| 007 | Technical parameters for EH&S Expert are not fully specified |
| 008 | Select at least one composition type |
| 009 | Enter value for parameter &1 |
| 010 | Enter at least one usage |
| 011 | There are no objects to save the default parameters for |
| 012 | This rating is already in the table |
| 013 | The compliance check result is already in the database |
| 014 | Compliance check &1 is not found |
| 015 | Compliance check &1 has been saved |
| 016 | Lock failure |
| 017 | Default parameters for some of the specifications are locked by user &1 |
| 018 | Parameter variant &1 is locked by user &2 |
| 019 | The validity area entered is already assigned to this rating |
| 020 | There are multiple objects; default parameters cannot be determined |
| 021 | There are no default parameters for specification &1 |
| 022 | Parameter variant &1 is not available |
| 023 | Default parameters have been saved |
| 024 | Parameter variant &1 has been saved |
| 025 | Compliance check &1 has been started in the background |
| 026 | You are not authorized to start the compliance check |
| 027 | Variant name must not be initial |
| 028 | Maintain the calculation ID |
| 029 | Calculation ID &1 already assigned to composition type &2 |
| 030 | Calculation ID &1 assigned to multiple composition types (&2 and &3) |
| 031 | Background job creation has failed |
| 032 | Variant &1 deleted |
| 033 | RFC destination &1 does not exist |
| 034 | Data provider &1 does not exist |
| 035 | Data origin &1 does not exist |
| 036 | No results found; check the log for details |
| 037 | Calculation ID not defined for composition type &1 |
| 038 | Composition type not defined for calculation ID &1 |
| 039 | Select at least one line |
| 040 | *** GOS service messages **** |
| 041 | Technical error; contact your system administrator |
| 042 | Variants do not exist; compliance check cannot start in background mode |
| 043 | Select only one line for this function |
| 044 | Compliance check not possible; select objects of the same object type |
| 050 | *** Navigation messages *** (placeholder) |
| 051 | Navigation error; no object was provided via navigation |
| 060 | |
| 061 | It is not possible to define usage rating without at least one val. area |
| 062 | No constraints have been set |
| 063 | VAT assignment for constraint &1 is missing |
| 064 | Constraint &1 is not listed |
| 065 | Unknown substance type &1 for substance &2 |
| 066 | Rating &1 does not exist |
| 067 | Validity Area &1 does not exist |
| 068 | Multiple value assignment for parameter &1 is not permitted |